Floor fan Speed 40 G-CH by Casafan
- wind machine, floor fan
- 110 watts of power
- 220 - 240 volts ~50 Hz voltage
- Air circulation 5.685 m³/h measured according to IEC 60879
- Color shiny chrome
- 3 levels via rotary switch
- ball bearing motor
- Including KlimaLex.de service
- 2.5m rubber hose for high mechanical loads H05RN-F 3 x 1.0 mm² with Schuko plug
The Fast and the Furious - wind, wherever you need it
- Protective grille with chrome fi nish.
- 3-speed rotary switch at the back of the grille.
- Vertical grade adjustable.
- Product can an be used wall mounted or with chain suspension (hooks and chain not included).
- Stable, tilt-free, chromed tubular frame with rubber feet.
- Useful transport handle and cable coil at the back side of protective grille.
- Powerful aluminium blade, matt black.
- Optional 5 speed transformer (ETWZ 1,0 # 891020) for regulation between a whisper quiet breeze and high performance available.
| Voltage | 220-240 volts ~50Hz |
| degree of protection | IP 20 |
| Maximum engine power | 110 watts |
| Special features of the floor fan | Protection class I, all-pole on/off switch, for commercial use |
| Impeller Diameter | 400mm |
| Basket diameter | 440mm |
| color | Glossy Chrome |
| Maximum Air Flow | approx. 5.685m³/h |
| Number of Levels | 3 levels with rotary switch |
| Maximum RPM | 1305 rpm |
| Material | Chrome-plated steel, polished |
| Cable | 2.5 m supply line H07RN 3 1.0 mm², with Schuko plug |
| Picture | Product | Power max. | Air performance max. | Max. revolutions | Impeller / basket diameter | Art.-No. | Price |
|---|---|---|---|---|---|---|---|
![]() |
Drum ventilator DF600 IP54 SL | 123 Watts | 13.000 m³/h | 870 R/min | 600 mm / 680 mm | 306090 | 399,99 € Price incl. 19% VAT plus Shipping |
![]() |
Drum Fan DF800 IP54 SL | 123 Watts | 15.650 m³/h | 870 R/min | 750 mm / 830 mm | 308095 | 479,99 € Price incl. 19% VAT plus Shipping |
![]() |
Floor fan Speed 40G-CH wind machine | 110 Watts | 5.685 m³/h | 1305 R/min | 400 mm / 440 mm | 304008 | 129,99 € Price incl. 19% VAT plus Shipping |
![]() |
Floor fan Speed 50G-CH Windmachine | 120 Watts | 7.860 m³/h | 1310 R/min | 500 mm / 550 mm | 305008 | 149,99 € Price incl. 19% VAT plus Shipping |
![]() |
Floor-fan FLOOR2PROTECT | 120 Watts | 10.700 m³/h | 1250 R/min | 455 mm / 495 mm | 304515 | 199,99 € Price incl. 19% VAT plus Shipping |
![]() |
CasaFan AIROS SILENT – Powerful Floor Fan with quiet EC Motor | 90 Watts | 10.023 m³/h | 850 R/min | 442 mm / 514 mm | 64505 | 189 € Price incl. 19% VAT plus Shipping |
Safety informations
- The voltage indicated on the nameplate must correspond to the available mains voltage. The domestic electrical system must be earthed and properly fused.
- Only operate the unit when completely assembled!
- Position the mains cable such that no danger of tripping is possible in order to avoid throwing the unit.
- If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person in order to avoid a hazard
- The unit may only be operated on level, stable ground. Do not place on tables or similar.
- Do no push objects through the guard. Any loose objects which could be sucked in are to be removed from the suction area before switching the fan on. Keep loose clothing, such as scarves with fringes, away from the guard.
- The units are never be touched when having wet or moist hands. The units are never be used if you are barefooted.
- Do not expose the fan to a direct water jet.
- Never immerse an electrical device in water or other liquids.
- Extension cords must be tested by a qualified technician and be suitable for the specified performance.
- Do not expose the device to harmful environmental influences (rain, strong sunlight, etc.).
- To unplug the power cord from the outlet, pull on the plug and not the cord.
- Switch off the device and pull the plug when not in use, prior to cleaning, and when moving the fan to a different location.
- Do not use the device in locations where it could fall or be knocked into water. Never reach for the device if it falls into water. Turn off the power at the circuit breaker immediately and then pull the plug.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understands the hazards involved.
- Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- Dispose of the packaging material in an environmentally friendly manner and inaccessible to children. There is a danger of suffocation, e.g. by swallowing!
About this operating instructions
Before using the CasaFan fan, read the operating instructions carefully. Keep the operating instructions within reach. Never pass the fan onto another person without the operating instructions.
Explanation of symbols:
Warning: Dangerous electric voltage Warns the user of the danger to the life an health due to electrical voltage.
Caution: Indicates risks to your health and possible injury risks.
Important: Warns of environmental and material damage.
Intended use: The floor fan Speed-G is used for indoor air circulation with non-aggressive room air in compliance with the safety instructions and the technical data. It can be used in commercial applications. Wall mounting is possible as an option.
Improper use: The use outdoors, in machines, in garages and in rooms at risk of fire and explosion is not permitted. Modifications to the device are not permitted.
Caution: Risk of tipping over! Only place the fan on a stable, level surface. Do not place on tables or similar.
Important: Risk of overheating! Keep at least 50 cm away from objects and walls.
Warning: Risk of injury and fire! Check the mains cable and the mains plug for damage regularly, but absolutely before each use. If damage is visible, do not use the device again.
Caution: Strong air flow!
- Do not point the fan directly at people.
Behaviour in an emergency
Warning: Risk of injury! Switch off the device immediately in case of visible damage, unusual noise, strong vibration and/or malfunction.
1. Pull the mains plug from the socket in an emergency.
2. Take persons out of the danger area.
3. Secure the fan against start-up.
- The fan must not be put back into operation until a qualified electrician has eliminated the cause of the fault and released it for reuse.
Maintenance/cleaning instructions
Warning: Disconnect the device from the mains supply by unplugging the plug or switching off the electrical system before carrying out any cleaning or maintenance work.
- Routine maintenance must be carried out once a year, earlier if it is very dirty.
- Clean the surface of the housing and the protective grille with a dry cloth and a soft brush. Do not use petrol or a similarly inflammable cleaning agent.
- The device is otherwise maintenance-free.
Storage
- If you are not going to use the fan for a long time, keep it in a dry room.
- You can also cover your unit to protect it from dust or dirt deposits.
Repair
Warning: Repairs may only be carried out by qualified personnel a qualified electrician. Improperly repaired devices pose a great danger to the health and life of the users of the device.
- If the mains cable to this unit is damaged, then it can only be repaired by a repair workshop named by the manufacturer.
Source: manufacturer's operating instructions (CasaFan SPEED G 40 50).
- Shipping Weight
- 6.192 kg