Speed 2 Protect floor-fan
- offer-fan
- certified for commercial use
- 123 Watt
- 220-240 Volt
- protection class IP54
- air Circulation 10.700 m³/h as per EN 60879
- 495 mm protctione basket
- protective grille, housing, frame and stand Steel with double corrosion protection coating
- colour white
- 2-pole power switch
- 3 Steps by means of encapsulated pressure switch
- vertical inclination adjustable from 130°
- stable design with carrying handle
- encapsulated, ball bearing mounted motor
- cable 2.5m rubber hose cable for high mechanical load H07RN-F 3 x 1.0 mm² with Schuko plug
Technical details FLOOR2PROTECT floor fan
| Voltage | 220-240 Volt/~50Hz |
| Power motor max. | 120 watt |
| Special features | safety class I, for commercial use, IP54 |
| Blade dia Ø | 455 mm |
| Grille Ø dia | 495 mm |
| Colour | white, Two-coat corrosion protection coating |
| Air flow | 10700 m³/h |
| Dimensions (WxHxD) | 535 x 520 |
| Anzahl der Stufen | 3 Steps with encapsulated pressure switch |
| Rev. max. | 1250 RPM |
| Material | aluminium, metal |
| Basket inclination | 130° |
| Power cord | 2,5 m Supply line H07RN 3 1,0mm², with Schuko plug IPX4 |
certified according to machinery directive 2006/42/EC Part 1 for commercial use
![]() |
![]() Warranty conditions |
![]() |
![]() |
![]() |
| Picture | Product | Power max. | Air performance max. | Max. revolutions | Impeller / basket diameter | Art.-No. | Price |
|---|---|---|---|---|---|---|---|
![]() |
Drum ventilator DF600 IP54 SL | 123 Watts | 13.000 m³/h | 870 R/min | 600 mm / 680 mm | 306090 | 399,99 € Price incl. 19% VAT plus Shipping |
![]() |
Drum Fan DF800 IP54 SL | 123 Watts | 15.650 m³/h | 870 R/min | 750 mm / 830 mm | 308095 | 479,99 € Price incl. 19% VAT plus Shipping |
![]() |
Floor fan Speed 40G-CH wind machine | 110 Watts | 5.685 m³/h | 1305 R/min | 400 mm / 440 mm | 304008 | 129,99 € Price incl. 19% VAT plus Shipping |
![]() |
Floor fan Speed 50G-CH Windmachine | 120 Watts | 7.860 m³/h | 1310 R/min | 500 mm / 550 mm | 305008 | 149,99 € Price incl. 19% VAT plus Shipping |
![]() |
Floor-fan FLOOR2PROTECT | 120 Watts | 10.700 m³/h | 1250 R/min | 455 mm / 495 mm | 304515 | 199,99 € Price incl. 19% VAT plus Shipping |
![]() |
CasaFan AIROS SILENT – Powerful Floor Fan with quiet EC Motor | 90 Watts | 10.023 m³/h | 850 R/min | 442 mm / 514 mm | 64505 | 189 € Price incl. 19% VAT plus Shipping |
Safety informations
- The voltage indicated on the nameplate must correspond to the available mains voltage. The domestic electrical system must be earthed and properly fused.
- Only operate the unit when completely assembled!
- Position the mains cable such that no danger of tripping is possible in order to avoid throwing the unit.
- If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person in order to avoid a hazard
- The unit may only be operated on level, stable ground. Do not place on tables or similar.
- Do no push objects through the guard. Any loose objects which could be sucked in are to be removed from the suction area before switching the fan on. Keep loose clothing, such as scarves with fringes, away from the guard.
- The units are never be touched when having wet or moist hands. The units are never be used if you are barefooted.
- Do not expose the fan to a direct water jet.
- Never immerse an electrical device in water or other liquids.
- Extension cords must be tested by a qualified technician and be suitable for the specified performance.
- Do not expose the device to harmful environmental influences (rain, strong sunlight, etc.).
- To unplug the power cord from the outlet, pull on the plug and not the cord.
- Switch off the device and pull the plug when not in use, prior to cleaning, and when moving the fan to a different location.
- Do not use the device in locations where it could fall or be knocked into water. Never reach for the device if it falls into water. Turn off the power at the circuit breaker immediately and then pull the plug.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understands the hazards involved.
- Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- Dispose of the packaging material in an environmentally friendly manner and inaccessible to children. There is a danger of suffocation, e.g. by swallowing!
About this operating instructions
Before using the CASAFAN fan, read the operating instructions carefully. Keep the operating instructions within reach. Never pass the fan onto another person without the operating instructions.
Explanation of symbols:
WARNING: Electric voltage! Warns the user of the danger to the life an health due to electrical voltage.
CAUTION: Indicates risks to your health and possible injury risks.
Intended use: The fan is for circulating room air. It can be used indoors and outdoors in compliance with the technical data and safety instructions. It is acc. Machinery Directive 2006/42/EC suitable for commercial use.
Improper use: The use in machines, in garages and in rooms at risk of fire and explosion is not permitted. Modifications to the device are not permitted.
CAUTION: Risk of injury! Only place the fan on a stable, level floor. Do not place on tables or similar.
WARNING: Risk of injury and fire! Check the mains cable and the mains plug for damage regularly, but absolutely before each use. If damage is visible, do not use the device again.
Behaviour in an emergency
CAUTION: Risk of injury! Switch off the device immediately in case of visible damage, unusual noise, strong vibration and/or malfunction.
1. Pull the mains plug from the socket in an emergency.
2. Take persons out of the danger area.
3. Secure the fan against start-up.
- The fan must not be put back into operation until a qualified electrician has eliminated the cause of the fault and released it for reuse.
Maintenance/cleaning instructions
WARNING: Disconnect the device from the mains supply by unplugging the plug or switching off the electrical system before carrying out any cleaning or maintenance work.
- Routine maintenance must be carried out once a year, earlier if it is very dirty.
- Clean the surface of the housing and the protective grille with a dry cloth and a soft brush. Do not use petrol or a similarly inflammable cleaning agent.
- The device is otherwise maintenance-free.
Storage
- If you are not going to use the fan for a long time, keep it in a dry room.
- You can also cover your unit to protect it from dust or dirt deposits.
Repair
WARNING: Repairs may only be carried out by qualified personnel a qualified electrician. Improperly repaired devices pose a great danger to the health and life of the users of the device.
- If the mains cable to this unit is damaged, then it can only be repaired by a repair workshop named by the manufacturer, due a special tool being needed.
Source: manufacturer's operating instructions (CasaFan FLOOR2PROTECT IP54 SL).
- Product type
- Floor Fan
- Shipping Weight
- 9 kg