CA 150 Q MD E RF roof pipe centrifugal fan

CA 150 Q MD E RF roof pipe centrifugal fan
MSRP 392,70 € −11 %
incl. VAT, plus shipping (Germany from 9,90 €)
or pay directly with
OR

Available again from 06.11.2026
Product number: CasaFan.16142 · EAN: 8010300161426

Manufacturer: Vortice S.p.A., Strada Cerca, 2 Frazione di Zoate, 20067 Tribiano, Mailand, Italien, export@vortice-italy.com

Vortice CA MD E RF Roof Fan CA 150 Q MD E RF – Centrifugal Roof Fan with Horizontal Discharge

The Vortice CA MD E RF roof fan CA 150 Q MD E RF is the professional solution for reliable extraction in residential, commercial, and industrial buildings. As a robust centrifugal roof fan with horizontal air discharge, this series was specifically developed for connection to ventilation ducts with a nominal diameter of 150 mm . It ensures continuous, powerful extraction of stale, humid, or polluted air over the roof.

Highlight of the CA MD E RF Series: Extremely Weather-Resistant Steel Construction
The casing is made of galvanized sheet steel with a high-quality, corrosion-resistant polyester coating. The weatherproof cowl reliably protects the fan from rain, snow, and extreme weather conditions – guaranteed durable and low-maintenance for outdoor use!

Maximum Performance, Durability & Easy Roof Installation

Whether in apartment buildings, catering facilities, offices, workshops, or warehouses: The Vortice CA MD E RF delivers high pressure performance, allowing it to easily overcome long duct runs. The backward-curved centrifugal impeller guarantees high performance while optimizing noise levels. Thanks to the well-thought-out mounting base, installation on flat or pitched roofs is precise and secure.

Your Benefits at a Glance:

  • ✓ Weatherproof Casing: Galvanized sheet steel with baked-on polyester coating for lasting corrosion protection.
  • ✓ Horizontal Discharge (RF): Optimized air outlet protects the roof surface and prevents exhaust air backflow.
  • ✓ Powerful AC Motor: 2-speed, ball-bearing motor with thermal overload protection for continuous operation.
  • ✓ High pressure output: Backward-curved centrifugal impeller moves air reliably even through long duct systems.
  • ✓ Speed Controllable: Infinitely variable or 2-speed adjustable via optional controllers / speed switches.
  • ✓ Safe Protection Rating: IPX4 splash-water protection for completely reliable operation on the roof.
Technical Data – Vortice CA MD E RF Series CA 150 Q MD E RF
Feature Value / Specification
Model CA 150 Q MD E RF
Maximum Airflow 312 m³/h
Maximum Pressure 307.9 Pa
Voltage 220-240 V
Current Draw 0.39 A
Power Consumption 50 watts
Sound Pressure Lp-2m 37.5 dB(A)
Maximum Speed 2430 RPM
Protection Rating IP44
Protection Class Class I (Earthed)
Max. Medium Temperature 50 °C
Nominal Diameter / Connection 150 mm
Casing Material Galvanized sheet steel
Colour Light Grey (RAL 7035)
Discharge Direction Horizontal (RF = Roof Fan horizontal)
Number of Speeds 2 speeds (controllable via optional step switch or speed controller)
Motor Infrastructure 2-speed AC motor, ball-bearing, thermal overload protection, dynamically balanced impeller
Fan Type Centrifugal Roof Fan / Exhaust Fan
Special Features Weatherproof cowl, corrosion-resistant steel casing, integrated mounting flange

Scope of Delivery

  • 1x Vortice CA MD E RF Roof Fan
  • 1x Sealing & mounting material for duct connection
  • 1x Detailed installation & operating manual
IP44 IP44 splash protection

Overview of Model Variants (W, E & RF):

Within the Vortice CA Series, the model designations indicate the specific design:
• “MD” (Medium Duty / Metal Duct): Version with robust metal casing for demanding ventilation tasks.
• “RF” (Roof Fan): Dedicated roof fan version with weatherproof cowl and horizontal discharge.
• “E” (Electronic / Eco): AC motor for continuous operation.
• “W” (Wall): Wall-mounted variant of the series for direct façade ventilation.


Safety instructions

Warning: this symbol indicates that care must be taken to avoid injury to the user

  • Always use the product for the purpose it was intended, as specified in this booklet.
  • After removing the product from its packaging, ensure that it is not damaged. If in doubt please contact a Vortice authorised Technical Assistance Centre immediately. Never leave packaging parts within reach of children or disabled persons.
  • The use of any electric device requires compliance with a few fundamental rules, including:
  • Never touch it with wet or humid hands.
  • Never touch it when barefoot.
  • Do not allow use by unsupervised children or disabled persons.
  • Do not use the unit in the presence of flammable substances or vapours such as alcohol, insecticides, gasoline, etc.
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Children shall not play with the appliance.
  • Cleaning and user maintenance shall not be made by children without supervision.
  • Precautions must be taken to prevent gas coming from the gas flue pipe or from other fuel combustion units from entering into the room.
  • Products installed without a protective device for moving parts must be installed at a height greater than 2.3 m above the floor level.
  • Units equipped with manual reset thermal breaker device

In order to avoid any danger of accidental reset of the thermal breaker device, units must not be powered by an external switch device such as a timer, or must not be connected to a circuit that is regularly powered or disconnected from power utilities.

Caution: this symbol indicates that care must be taken to avoid damaging the appliance

  • Do not make changes of any kind to the unit.
  • Do not leave the device exposed to adverse weather conditions (rain, sun, etc.).
  • Do not rest objects on the device.
  • Periodically check device conditions. If imperfections are noted, do not use the unit and immediately contact a Vortice authorised Technical Assistance Centre.
  • Promptly contact a Vortice authorised Assistance Centre in the event of unit malfunction and/or failure and request the use of original Vortice spare parts for any repairs.
  • If the unit falls or receives a strong blow, immediately have it inspected at a Vortice authorised Technical Assistance Centre.
  • Only connect the device to the mains supply/ electrical outlet if plant/outlet capacity is suitable for its maximum power. If otherwise, immediately seek assistance from a professionally qualified person.
  • Switch off the main switch on the system when: a) a malfunction is detected, b) you decide to perform external cleaning maintenance, c) when you decide not to use the device for prolonged periods.
  • It is essential to ensure that sufficient air re-enters the room, in order to guarantee product operation. If a combustion-powered, non air-tight device is installed in the room (water heater, methane stove, etc.), please ensure that air re-entry also guarantees the perfect combustion of said device.
  • The unit cannot be used as an activator for water heaters, stoves, etc. nor should it discharge into hot air ducts.
  • The device must suction in a single duct (used by this product only), or directly outside.
  • Never cover the two intake grilles and the device return duct, to ensure optimal air passage.
  • The maximum temperature for product operation is:
  • = 55°C for models 150-160-200-250-315
  • = 50°C for models 100-125-150Q
  • An omnipolar switch with a contact opening distance of 3 mm or higher should be provided for installation, enabling complete disconnection under overvoltage category III conditions.
  • Products equipped with single-phase wiring (M) engines ALWAYS require connection to 220-240V (or only 230V where required) single-phase lines. Any kind of modification shall be considered as product tampering and shall nullify the relative warranty.
  • No specific adjustment is necessary as the devices operate at nominal frequencies without a preliminary setting.
  • Thermal protection devices:
  • Manual reset thermal protector

The following models are equipped with a manual reset thermal protector

If the thermal protector is triggered, please contact qualified personnel or Vortice authorised Technical Assistance Centre. If the problem persists after the reset operation, check the electrical system to which the unit is connected. In this case, please contact a Vortice authorised Technical Assistance Centre or professionally qualified personnel.

  • The electrical specifications correspond to the ones on the data label A (fig.A).

Source: manufacturer's operating instructions (Vortice CA MD E RF, pages 9–11).

Air pressure max in Pa
307.9 Pa
Size
150 mm
Sound pressure
37.5 dB(A)
Model
CA 150 Q MD E RF
Amperage
0.39 A
Temperature max.
50 °C
Power
50 watts
Manufacturer
Vortice
Material
Galvanized sheet steel
Air output
312 m³/h
Voltage
220-240 V
IP protection class
IP44
Specials
3 stages
Revolutions
2430 RPM
Shipping Weight
8 kg
This item has already been rated. A written review has not yet been submitted.

 
from 14,99 €

incl. 19 % VAT, excl. Shipping costs

 
19,99 €

incl. 19 % VAT, excl. Shipping costs

Base price per piece: 10,00 €
RRP 79,73 €
74,99 €

incl. 19 % VAT, excl. Shipping costs

RRP 177,31 €
159,99 €

incl. 19 % VAT, excl. Shipping costs

RRP 130,90 €
from 74,99 €

incl. 19 % VAT, excl. Shipping costs

 
24,99 €

incl. 19 % VAT, excl. Shipping costs

RRP 80,92 €
74,99 €

incl. 19 % VAT, excl. Shipping costs

RRP 98,77 €
94,99 €

incl. 19 % VAT, excl. Shipping costs

RRP 213,01 €
189,99 €

incl. 19 % VAT, excl. Shipping costs

RRP 78,54 €
74,99 €

incl. 19 % VAT, excl. Shipping costs

RRP 111,86 €
109,99 €

incl. 19 % VAT, excl. Shipping costs

RRP 152,09 €
from 139,99 €

incl. 19 % VAT, excl. Shipping costs

RRP 70,21 €
64,99 €

incl. 19 % VAT, excl. Shipping costs

RRP 140,42 €
129,99 €

incl. 19 % VAT, excl. Shipping costs

RRP 83,30 €
79,99 €

incl. 19 % VAT, excl. Shipping costs