Vortice flush-mounted housing QE-B I K90 S 2L

Vortice flush-mounted housing QE-B I K90 S 2L: NW 75/80
MSRP 214,20 € −11 %
incl. VAT, plus shipping (Germany from 9,90 €)

or pay directly with
OR

Available again from 11.12.2026
Product number: CasaFan.11569

Manufacturer: Vortice S.p.A., Strada Cerca, 2 Frazione di Zoate, 20067 Tribiano, Mailand, Italien, export@vortice-italy.com

Flush-mounted housing Vortice QE-B I K90 S 2L with K90 fire-protection casing

The flush-mounted housing Vortice QE-B I K90 S 2L is the installation housing for fan inserts of the Quadro EVO series (bathroom fans). It has a K90 fire-protection casing (according to the manufacturer) and is intended for installation in walls, ceilings or F90 ventilation shafts.

The ABS plastic housing has a stainless steel outlet spigot (NW 75/80) with K90 fire-protection shut-off element (TUM-certified according to the manufacturer), an airtight non-return damper according to DIN 18017-3 and a plaster protection cover. The manufacturer states the general building approval Z-51.1-469.

At a glance

  • K90 fire-protection casing (according to the manufacturer)
  • Outlet spigot NW 75/80, stainless steel
  • Airtight non-return damper according to DIN 18017-3
  • Plaster protection cover included

Technical data

Property Value
Nominal width NW 75/80 mm
Fire protection casing K90 (according to the manufacturer)
Non-return damper airtight, according to DIN 18017-3 (according to the manufacturer)
Approval General building authority approval Z-51.1-469 (according to the manufacturer)

Manufacturer: Vortice S.p.A. Technical data according to manufacturer documents, subject to change.

Notes and accessories

  • The fan insert (bathroom fan) is not included and has to be ordered separately. Please check the suitability for the installation location and the fire protection requirements before installation.

Safety instructions

Safety information of the matching fan insert (Vortice Quadro Evo):

Warning: this symbol indicates that care must be taken to avoid injury to the user

  • Do not use the appliance for functions other than those described in this booklet.
  • Having removing the appliance from its packaging, ensure that it is intact and undamaged: if in doubt, seek advice immediately from a qualified professional or contact a Vortice Technical Support Centre. Do not leave packaging within the reach of children or individuals with disabilities.
  • Certain fundamental rules must be observed when using any electrical appliance, including: a) never touch appliances with wet or damp hands; b) never touch appliances while barefoot.
  • If the appliance is to be disconnected from the power supply and no longer used, store it out of reach of children and individuals with disabilities.
  • Do not operate the appliance in the presence of flammable substances or vapours, such as alcohol, insecticides, petrol, etc.
  • This appliance can be used by children no less than 8 years of age and by individuals with limited physical, sensory or mental capacities, or by inexperienced or untrained individuals, provided that they are supervised or have been instructed in safe use of the appliance and understand the associated risks. Children must not play with the appliance. Cleaning and maintenance procedures that can be undertaken by the user must not be entrusted to children, unless under supervision.
  • Install the appliance at least 2.3 m from the floor.

Caution: this symbol indicates that care must be taken to avoid damaging the appliance

  • Do not make modifications of any kind to the appliance.
  • Do not leave the appliance exposed to the elements (rain, sun, etc.).
  • Inspect the appliance periodically for visible defects. If the appliance is defective in any way, do not use it; contact a Vortice Technical Support Centre without delay.
  • If the appliance does not function correctly or develops a fault, contact a Vortice Technical Support Centre without delay. Ensure that only original Vortice replacement parts are used for any repairs.
  • Should the appliance be dropped or suffer a heavy blow, have it checked immediately by your Vortice Service Centre.
  • The electrical system to which the appliance is connected must comply with current regulations.
  • The appliance is double insulated and therefore does not require an earth connection at the socket or fixed wiring point.
  • Connect the appliance to the electrical power supply/socket only if the rated power of the supply is compatible with the maximum rated power of the appliance. If not, contact a professional electrician without delay.
  • Regulation of the timer on TIMER and T HCS models must be entrusted to a qualified professional.
  • Switch off the appliance at the main switch: a) if the appliance does not function correctly; b) before cleaning the outside of the appliance, c) if the appliance is not to be used for any length of time.
  • The room must be ensured an adequate supply of fresh air for the appliance to function as it should. In the event that there is a non room sealed fuel-burning appliance (e.g. water heater, gas stove, etc.) installed in the same room, check that the supply of fresh air is also sufficient for the burner of this appliance to function efficiently.
  • The appliance cannot be used to pilot the operation of water heaters, stoves, etc.; neither must it expel air into the hot air ducts of such appliances.
  • The appliance must expel air into a single duct (connected only to this particular product) or directly to the outside of the building.
  • The flow of air or fumes extracted by the fan must be clean (i.e. devoid of grease, soot, chemical and corrosive agents, or explosive and flammable gases).
  • Make certain that the inlet grille and outlet ports of the appliance are not masked or obstructed, so as to ensure a free flow of air.
  • Specifications for the power supply must correspond to the electrical data on data plate A.
  • The appliance must be installed by a professionally qualified electrician.
  • A multi-pole switch must be used to install the appliance. The contact opening gap must be no less than 3 mm.

Source: manufacturer's operating instructions (Vortice Quadro Evo, pages 10–11).