Brune dehumidifier Dehumid HP50 with radio hygrostate

Brune dehumidifier for the drying of living spaces as well as basements

Manufacturer: Brune, Luftbefeuchtung Proklima GmbH, Schwarzacher Straße 13, 74858 Aglasterhausen, Deutschland, mail@brune.info

Dehumidification with the Brune dehumidifier Dehumid HP50 Funk

The Brune dehumidifier Dehumid HP50 Funk is the ideal solution for anyone seeking effective and comfortable control of humidity in their spaces. This powerful and mobile dehumidifier offers high dehumidification performance. It is perfect for construction sites, living areas, office and basement rooms, archives, and museums with a volume of up to 250 m³.

Compared to the main variant, the Brune Dehumidifier Dehumid HP 25, the variant Dehumid HP50 with Radio Hygrostat offers additional benefits. With the optional radio hygrostat, you can precisely set the desired humidity level. The device automatically turns on when the set humidity exceeds and turns off when the value drops below. This allows for continuous humidity regulation, protecting your valuable items from moisture damage and mold.

Here are the key similarities and differences of the Brune Dehumidifier variants:

  • Dehumidification Performance: The HP50 offers higher dehumidification performance compared to the HP25.
  • Radio Hygrostat: The HP50 is equipped with a radio hygrostat, while the HP25 does not have this feature.
  • Models: Both models offer high dehumidification performance.
  • Application Area: Both models are suitable for similar application areas, but the HP50 is optimized for larger volumes.
  • Mobility: Both devices are mobile, but the HP50 has additional features for easy handling.
Technical Data
Property Value
Dehumidification Performance (Liters/Day) at 25°C / 80% rF 24
Collection Tank (Liters) 6.5
Air Volume (m³/Hour) 500
Room Volume up to (m³) 250
Power Consumption at 230V~50 Hz 570 Watts
Sound Pressure in dB (A) approx. 42 - 45
Dimensions in mm: Width Height Depth 330 560 355
Condensate Hose Connection in mm 14 mm (9/16)
Operating Temperature Range +5 - 32°C / 35-90% r.F.
Empty Weight (in kg) approx. 25

The Brune Dehumidifier Dehumid HP50 Funk is thus the perfect choice for anyone who values precise and reliable humidity regulation. Whether for private or commercial use, this dehumidifier protects your spaces from excessive moisture and ensures a pleasant indoor climate.


Safety instructions

1. General safety instructions

The operator must make the operating instructions available to the user and make sure that the user understands the contents.

  • The appliance contains a slightly flammable refrigerant.
  • This is a mixture of a slightly flammable (A2L) and a fluorinated (A1) refrigerant.
  • The appliance contains flammable refrigerant / Read the supplied instructions/warnings
  • Read the maintenance instructions
  • Read the operating instructions

The appliance can be used by children aged 8 and over and by persons with reduced physical, sensory or mental abilities or lack of experience and/or knowledge if they are supervised or have been instructed in the safe use of the appliance and have understood the resulting hazards.

Children must not play with the appliance. Cleaning and user maintenance must not be carried out by children without supervision.

ATTENTION Fire hazard/flammable materials – PLEASE BE SURE TO OBSERVE

  • Do not use any means other than those recommended by the manufacturer to accelerate the defrosting process or to clean the appliance.
  • The appliance may only be stored in a room without continuously operating ignition sources (e.g. open fire, operating gas or electric heaters).
  • Do not pierce or burn.
  • Please note that refrigerants may not have an odour.
  • The individual appliance should be installed, operated and stored in a room with a floor area of more than 4m².
  • Compliance with national gas regulations must be observed.
  • R454C has a low global warming potential (GWP) of 146 and an ozone depletion potential (ODP) of 0.
  • The maximum amount of refrigerant is 0.650kg.
  • Keep the ventilation openings of the appliance free from obstructions.
  • The appliance must be stored so that no mechanical damage occurs.
  • Warning! The appliance must be stored in a well-ventilated area in which the room size corresponds to the room size specified for operation.

2. Safety instructions

ATTENTION This dehumidifier must not be used in rooms under the following conditions:

  • potentially explosive atmosphere
  • extremely polluted atmosphere
  • high concentration of solvents
  • extremely high dust content

Always connect the appliance earthed: Only operate the appliance with a earthing-contact plug and an earthed socket. The earthing-contact plug is an essential safety feature that helps prevent a risk of fire or electric shock.

Protect the power cable from damage: Never operate an appliance with a damaged power cable, as this can lead to fire or electric shock. If the power cable is damaged, it must be replaced with a cable of the same type and the same amperage.

Extension cables: Extension cables must be earthed and be able to supply the appropriate voltage to the appliance.

Handle the appliance with care: Do not drop the dehumidifier; do not throw it and do not open it by force. Rough handling can damage the components or the cables and cause hazards.

Operate the appliance on a stable surface: Only operate the appliance on a stable, level surface, for example on the floor or a sturdy table, so that the dehumidifier cannot fall and cause injury.

Keep the appliance away from water: Never operate the appliance in running or standing water - risk of injury from electric shock! Do not store or operate the appliance outdoors. If electrical cables or components become wet, dry them thoroughly before using the appliance. If in doubt, please do not switch on the dehumidifier. Please contact an authorised dealer or a recognised workshop.

Keep air inlets clear: Do not place the dehumidifier too close to curtains, walls or other places that could obstruct the air inlet. This can lead to overheating of the appliance and a risk of fire or electric shock.

Keep the filter clean: Always use a clean air filter. Prevent any material from clogging the filter. This can lead to overheating of the dehumidifier. Never use the appliance without a filter. Check and clean the filter if necessary, always before you switch on the dehumidifier. Prevent oil, grease or other contaminants from entering the appliance.

Keep electrical components dry: Never let water get into the electrical components of the dehumidifier. If electrical cables or components become wet for any reason, dry them thoroughly before using the appliance. If in doubt, please do not switch on the dehumidifier. Please contact an authorised dealer or a recognised workshop.

The operator must make the operating instructions available to the user and ensure that the user understands the contents.

5. Assembly and transport Please observe the following instructions for assembly and transport:

  • The air inlets and outlets must not be covered while the appliance is in operation.
  • The dehumidifier must be switched off before any transport. Unplug the mains plug from the socket and empty the water container.
  • During transport, the appliance must be secured on a firm surface so that it does not roll away.
  • Always transport the dehumidifier upright.
  • This dehumidifier is only suitable for drying air.
  • If the appliance is stored or transported in a horizontal position for several minutes, it must then be set up upright for at least 30 minutes before commissioning. This ensures that the oil can flow back into the compressor and the compressor is not damaged.

6. Operating instructions ATTENTION

  • Only operate the dehumidifier in an upright position.
  • Connect the appliance to a standard socket with appropriate voltage and current.
  • If the appliance switches off for any reason, wait five minutes before switching it on again. This avoids damage to the compressor.
  • Check daily that the dehumidifier is working properly.
  • Protect floor surfaces from any spilled or leaking water.

Attention: Unplug the mains plug before working on the appliance.

10. Electrical connections This dehumidifier has been designed for an electrical installation of 220-240 V~50Hz. Make sure that the sockets are earthed and all safety precautions have been taken.

Source: manufacturer's operating instructions (Brune Dehumid HP 50).

Voltage
230 V
Depth
48 cm
Sound pressure
55 dB(A)
Color
Grey
Width
54 cm
Water tank
20 liters
Refrigerant
R 410 A
Max. Dehumidification capacity
50 liters/day
Hygrostat
Radio hygrostat
Room volume
0600 m³
Weight
45 kg
Power
950 watts
Fan
n/a
Display
LED
WiFi
no
Air inlet
n/a
Height
78 cm
IP protection class
no
Functionality
Condensation dryer
Air outlet
n/a
Working range
1 to 35°C
Manufacturer
Brune
Control
yes
Casing
Plastic and stainless steel
Operating time counter
yes
Air output
1000 m³/h
Product type
dehumidifier
Condensate pump
optional
Shipping Weight
52 kg
This item has already been rated. A written review has not yet been submitted.

 
24,99 €

incl. 19 % VAT, excl. Shipping costs

 
3,39 €

incl. 19 % VAT, excl. Shipping costs

RRP 2.963,10 €
2.599,99 €

incl. 19 % VAT, excl. Shipping costs

RRP 2.546,60 €
from 1.799,99 €

incl. 19 % VAT, excl. Shipping costs