Mobile dehumidifier Aerial AD 740

lightweight, compact dehumidifier Aerial AD 740
MSRP 2.963,10 € −12 %
incl. VAT, plus shipping (Germany from 69,90 €)

or pay directly with
OR

Immediately available! Delivery time 1-5 days.
* is valid for deliveries within Germany, for other countries please see Delivery Time
Product number: Aerial.14423 · EAN: 4260393632240

Manufacturer: Aerial, Dantherm Group A/S, Marienlystvej 65, 7800 Skive, Dänemark, info@danthermgroup.com

Aerial AD 740: Mobile Dehumidifier for Construction Drying and Water Damage Restoration

The Aerial AD 740 mobile construction dryer is designed for anyone who needs powerful and reliable dehumidification. With a dehumidification capacity of up to 34 litres per day (at 30 °C / 80 % RH), this condensation dehumidifier is suitable for water damage restoration and construction drying as well as for storage rooms, basements, garages, archives and waterworks.

The AD 740 belongs to the same series as the Aerial AD 20 mobile dehumidifier, but is designed for larger rooms: according to the manufacturer, it is suitable for heated rooms up to 500 m³ and unheated rooms up to 350 m³ (practical values for storage rooms). Condensate is collected in a 6.8-litre container; the unit switches off automatically when the container is full. Alternatively, direct drainage via a hose is possible, and with the optionally available pump kit, autonomous operation is also possible.

Key features at a glance:

  • Dehumidification capacity: 34 l/day at 30 °C / 80 % RH, 18 l/day at 20 °C / 60 % RH, 14 l/day at 15 °C / 60 % RH.
  • Robust housing: shock-resistant, UV-resistant plastic housing in AERCUBE® design with a durable, easy-to-clean surface; easy to open, clean and maintain.
  • Mobile and stable: two plastic wheels (Ø 190 mm) and a folding handle; high stability even during operation. Can be combined with all units of the AERCUBE® series, with fixing points for the AERCUBE® lashing system.
  • eDRY® control: multilingual electronics with target humidity setting (retained after power disconnection), two fan speeds, continuous and night mode, display of operating hours and actual/target humidity, "tank full" indicator light.
  • Calibrated energy meter: MID-compliant, non-resettable and readable even without power, practical for billing electricity consumption during construction drying.
  • Operational reliability: demand-controlled hot gas defrosting and automatic restart after a power failure.
  • Power consumption: 625 W at 30 °C / 80 % RH, 480 W at 20 °C / 60 % RH, 415 W at 15 °C / 60 % RH; maximum 800 W.

Here is an overview of the technical details of the Aerial AD 740 mobile construction dryer:


Technical Data
UnitAerial AD 740 dehumidifier
ManufacturerAerial (Dantherm Group)
Operating principleCondensation principle (heat pump principle with energy recovery)
Dehumidification capacity30 °C / 80 % RH: 34 l/day
20 °C / 60 % RH: 18 l/day
15 °C / 60 % RH: 14 l/day
Power consumption30 °C / 80 % RH: 625 W
20 °C / 60 % RH: 480 W
15 °C / 60 % RH: 415 W
Max. power consumption800 Watt
Air flowSpeed 1: 450 m³/h, speed 2: 550 m³/h
Operating range+5 °C to +34 °C, 35 % to 99 % RH
Suitability*Heated rooms up to 500 m³, unheated rooms up to 350 m³
CompressorHermetically sealed rotary compressor
FanEC axial fan, 2-speed
Refrigerant circuitCondenser and evaporator made of copper tubes with aluminium fins; service connector
DefrostingDemand-controlled hot gas defrosting
Condensate drainage6.8 l collection container with automatic shut-off when full; connector for 15 × 2 mm drain hose
Noise level51 dB(A)
Power supply230 Volt / 50 Hz, 4.5 m power cable with plug
Protection classIPX4
RefrigerantR454C; contains fluorinated greenhouse gases in a hermetically sealed system
HousingPlastic (PE), light grey
DimensionsHeight 690 mm, width 390 mm, depth 470 mm
Weight32 kg
Optional accessoriesCondensate drain hose 15 × 2 mm, pump kit, spare filter

* Practical values / empirical values provided by the manufacturer for storage rooms.


In summary, the Aerial AD 740 mobile construction dryer is a good choice for anyone who needs powerful and reliable dehumidification, whether for construction drying, after water damage or for long-term humidity control in storage rooms and basements.


Safety instructions

Intended use

Only use the dehumidifier to remove humidity from the air at atmospheric pressure in closed indoor rooms.

The dehumidifier is only suitable for users with reduced physical, sensory or mental abilities if appropriate supervision or detailed instruction on the use of the dehumidifier by a responsible person is ensured. Children must not use the dehumidifier.

Every user must have read and understood the operating instructions.

Intended use also includes compliance with the specified conditions of use (see page 5).

Foreseeable misuse

Any use that does not correspond to the intended use or goes beyond it is considered misuse and will void any warranty claims.

WARNING! Explosion due to flammable refrigerant!

  • Do not use any objects, other than those permitted by the manufacturer, to accelerate the defrosting process.
  • Only store the dehumidifier in rooms without permanent sources of ignition (e.g. open flames, an operating gas appliance or an electric heater).
  • Do not drill into or burn the dehumidifier.
  • Refrigerants are odourless!
  • Set up, operate and store the dehumidifier in a room with a floor area larger than 4 m².

WARNING! Electric shock from live components!

Spilling condensate onto live components can cause life-threatening electric shocks.

  • Before each change of location of the dehumidifier:
  • Pump out residual water: To do so, press “P” on the control panel. A small amount of water remains in the dehumidifier for technical reasons.
  • Switch off the dehumidifier and unplug the mains plug from the socket.

WARNING! Electrocution!

  • Work on electrical components may only be carried out by the manufacturer or authorised personnel.

WARNING! The dehumidifier must not be used under the following conditions:

  • In rooms with potentially explosive atmospheres.
  • In rooms with aggressive atmospheres, e.g. caused by chemicals.
  • In rooms with water with a pH value below 7.0 or above 7.4.

NOTE: At lower pH values there is a risk of corrosion for all metals.

  • In rooms with salt or liquids with a salt content > 1 %, e.g. brine baths.
  • In rooms with ozone-treated air, high solvent concentrations or extremely high dust pollution.

WARNING! Poisoning, burns, crushing during maintenance work!

  • Work on the internal components may only be carried out by the manufacturer or authorised personnel.
  • Repairs or maintenance work may only be carried out by the manufacturer or authorised personnel.

ATTENTION! Damage to property!

  • Only use original or approved spare parts.

In the event of a malfunction, switch off the dehumidifier and secure it against being switched on again accidentally.

WARNING! Crushing as a result of instability!

  • Preferably transport the dehumidifier in an upright position.
  • Always secure the dehumidifier against tipping over or slipping.
  • Always set up the dehumidifier on surfaces that are as level and firm as possible.

WARNING! Tripping over the drainage hose!

  • Before transporting the dehumidifier, disconnect the drainage hose from the appliance.

WARNING! Crushing, cutting from reaching into the air filter grille during transport!

  • Always transport the dehumidifier using the handles.
  • Do not reach into the air filter at the back of the dehumidifier.

CAUTION! Crushing or ergonomic damage when moving or transporting the dehumidifier!

  • Always transport the dehumidifier using the handles.
  • Avoid uncontrolled movements.

WARNING! Tripping over the connected drainage hose!

  • Route the drainage hose outside the walking area.
  • Fit safe and stable covers to the drainage hose.

CAUTION! Injuries due to loss of stability or uncontrolled movements of the dehumidifier!

  • Preferably transport the dehumidifier in an upright position.
  • Always secure the dehumidifier against tipping over or uncontrolled rolling away.
  • Always set up the dehumidifier on surfaces that are as level and firm as possible.

NOTE: The air must circulate freely. Do not cover the air openings. There must be a clearance of at least 1 m in front of the air outlet and the air filter.

Do not switch on a stored dehumidifier immediately. It may need an adjustment phase to the room temperature, especially after storage below 0 °C.

ATTENTION! Damage to property / inadequate appliance output due to incorrect connection of the condensate drain hose!

  • Do not bend the hose.
  • Do not place any objects on the hose.
  • Regularly check that condensate drains off safely.

Electrical connection Check the following points before connecting the dehumidifier electrically:

  • The mains voltage must correspond to the connection voltage in the technical data!
  • Provide an adequate fuse for the socket and the power supply!
  • Install an earth leakage circuit breaker in damp rooms and building sites!
  • The plug of the dehumidifier must be suitable for the socket of the building!
  • The socket used must be earthed!

NOTE: Allow the dehumidifier to rest in its final position for approx. 15 minutes before starting up and after transport. During this time the oil distributed in the refrigeration system and foamed up by transport flows back into the compressor.

WARNING! Damage to health from dust!

  • Vacuum the foam filter from both sides, wash and dry if necessary.
  • Only clean the dehumidifier with compressed air in open spaces.
  • Wear a protective mask and goggles.

ATTENTION! Damage to property!

  • Cleaning agents can damage surfaces. Only use mild detergents.

WARNING! Injury from electric shock!

  • The dehumidifier may only be repaired by the manufacturer or authorised personnel.

CAUTION! Injury!

  • Never stack more than four dehumidifiers on top of each other.
  • Always secure the dehumidifiers against tipping over.

Source: manufacturer's operating instructions (Aerial AD 20, as of 03_2019).

Sound pressure
51 dB(A)
Fan
axial
Control
Membrane keypad
Max. Dehumidification capacity
34 liters/day
Hygrostat
Built-in, electronically
Operating time counter
yes
Casing
Plastic
Voltage
230 V
Air outlet
At the back
Air inlet
At the front
Room volume
0500 m³
Water tank
6.8 liters
Manufacturer
Aerial
Display
LED
IP protection class
IPX4
Depth
47 cm
Width
39 cm
Height
69 cm
Refrigerant
R 454 C
Product type
dehumidifier
Weight
32 kg
Power
800 watts
Color
Grey
Functionality
Condensation dryer
Air output
550 m³/h
WiFi
no
Working range
1 to 34°C
Condensate pump
no
Area of Application
35–99 % rF
Shipping Weight
33 kg
This item has already been rated. A written review has not yet been submitted.

RRP 140,42 €
139,99 €

incl. 19 % VAT, excl. Shipping costs

RRP 2.546,60 €
from 1.799,99 €

incl. 19 % VAT, excl. Shipping costs

RRP 829,00 €
699,99 €

incl. 19 % VAT, excl. Shipping costs

 
399,99 €

incl. 19 % VAT, excl. Shipping costs