Product number: Aerial.14675 · EAN: 4260393632448

Manufacturer: Aerial, Dantherm Group A/S, Marienlystvej 65, 7800 Skive, Dänemark, info@danthermgroup.com

Replacement condensate pump for the Aerial AD 40 dehumidifier

Fully automatic pump kit for pumping out condensate for Aerial AD 40.
Product information
Condensate pump Poseidon MD 400
Manufacturer Aerial
Country of manufacture Germany
Material Pump: plastic, Back panel: metal
Color Back panel: dark grey
Service Button to empty the pump
Security Features Failure of the pump is signaled and the dehumidifier is switched off
Installation The pump goes into the dehumidifier with the back wall instead of the water tank deployed
Device-internal cabling via connectors
Power supply & control of the pump is provided by the dehumidifier
Drainage hose (not included) is connected via a plug-in coupling (inside Scope of delivery) on the rear wall
Type of connection Internal device: connector
More Set consists of pump, back panel & accessories

Technical Details
Drain hose Inner diameter 14 mm, outer diameter 18 mm (optionally available as an accessory)
Tank volume 1.8 liters
Head 4m
Workspace from + 3 °C to + 50 °C
Flow rate 192 litres/hr
Supply voltage 230 volts ~50Hz (via dehumidifier)
Maximum power consumption 85 watts
Degree of protection IP X4
Dimensions Width: 320mm
Height: 260mm
Depth: 170mm

Optional accessories:

Condensate drain hose 12 x 2 mm
Hose coupling
Hose clamps
Safety instructions

Foreseeable misuse

The pump kit may not be used:

  • In rooms with potentially explosive atmospheres.
  • In rooms with an aggressive atmosphere (e.g. caused by chemicals).
  • In rooms with water with a pH value below 7.0 or above 7.4.
  • In rooms with salt or liquids with a salt content > 1 %, e.g. brine baths.
  • In rooms with ozone-treated air, high solvent concentrations or high dust pollution.

WARNING! Electrocution! Working on live components or water on live components can cause life-threatening electrocution.

  • Avoid contact between water and live components.
  • Before changing the location of the dehumidifier and pump kit, switch it off and then press and hold down the button for manual pump out until there is no more condensate water flowing out of the hose. Then disconnect the mains plug.
  • Each time the pump kit is installed or removed, ensure that the safety relay for the dehumidifier is switched off and the mains cable is disconnected.
  • Check that the pump kit cables are not damaged.
  • Only allow the manufacturer or authorised personnel to carry out work on electric components.

WARNING! Electrocution! Electrocution may occur due to improper or faulty connection to the power supply.

  • Check that the connection cable is compatible with the pump kit connection on the dehumidifier.
  • Ensure that the connection cable is undamaged.

WARNING! Risk of burn!

  • Only allow the manufacturer or authorised personnel to carry out work on internal components.

CAUTION! Risk of injury if pump kit falls out! Pump kit with sliding lock/Secure the lock and check that it fits properly.

Complete emptying before transport and removal The pump must be completely emptied before transporting the dehumidifier and every time the pump kit is dismantled.

WARNING! Electrocution!

  • Before dismantling the pump kit and before transporting the dehumidifier, always make sure that the condensate water has been completely pumped out first.

WARNING! Risk of injury and burns during maintenance work!

  • Each time the pump kit is installed or removed, ensure that the safety relay for the dehumidifier is switched off and the mains cable is disconnected.
  • Only allow the manufacturer or authorised personnel to carry out repairs and maintenance work.
  • In the event of malfunctions, switch off the product and secure it so that it cannot be switched back on again.
  • Allow any hot components to cool sufficiently before working on them.

ATTENTION! Damage to property!

  • Cleaning agents can damage surfaces. Only use mild detergents.
  • Only use approved original spare parts.

ATTENTION! Device may be damaged if stored improperly

  • Never store pump kit below freezing.

ATTENTION! Risk from materials and substances

  • Sort materials according to type and recycle in accordance with local regulations.
  • When disposing of auxiliary and operating materials, observe the local regulations and information on the safety data sheets.

Source: manufacturer's operating instructions (Aerial pump kit).

Depth
17 cm
IP protection class
IPX4
Manufacturer
Aerial
Voltage
230 V
Width
32 cm
Working range
3 to 50°C
Power
85 watts
Weight
4 kg
Product type
condensate pump
Height
26 cm
Shipping Weight
4.2 kg
This item has already been rated. A written review has not yet been submitted.

 
3,99 €

incl. 19 % VAT, excl. Shipping costs

 
1.449,99 €

incl. 19 % VAT, excl. Shipping costs

RRP 2.546,60 €
from 1.799,99 €

incl. 19 % VAT, excl. Shipping costs