Replacement condensate pump for the Aerial AD 40 dehumidifier
Fully automatic pump kit for pumping out condensate for Aerial AD 40.| Condensate pump | Poseidon MD 400 |
| Manufacturer | Aerial |
| Country of manufacture | Germany |
| Material | Pump: plastic, Back panel: metal |
| Color | Back panel: dark grey |
| Service | Button to empty the pump |
| Security Features | Failure of the pump is signaled and the dehumidifier is switched off |
| Installation | The pump goes into the dehumidifier with the back wall instead of the water
tank deployed Device-internal cabling via connectors Power supply & control of the pump is provided by the dehumidifier Drainage hose (not included) is connected via a plug-in coupling (inside Scope of delivery) on the rear wall |
| Type of connection | Internal device: connector |
| More | Set consists of pump, back panel & accessories |
| Drain hose | Inner diameter 14 mm, outer diameter 18 mm (optionally available as an accessory) |
| Tank volume | 1.8 liters |
| Head | 4m |
| Workspace | from + 3 °C to + 50 °C |
| Flow rate | 192 litres/hr |
| Supply voltage | 230 volts ~50Hz (via dehumidifier) |
| Maximum power consumption | 85 watts |
| Degree of protection | IP X4 |
| Dimensions | Width: 320mm Height: 260mm Depth: 170mm |
Optional accessories:
Condensate drain hose 12 x 2 mmHose coupling
Hose clamps
Foreseeable misuse
The pump kit may not be used:
- In rooms with potentially explosive atmospheres.
- In rooms with an aggressive atmosphere (e.g. caused by chemicals).
- In rooms with water with a pH value below 7.0 or above 7.4.
- In rooms with salt or liquids with a salt content > 1 %, e.g. brine baths.
- In rooms with ozone-treated air, high solvent concentrations or high dust pollution.
WARNING! Electrocution! Working on live components or water on live components can cause life-threatening electrocution.
- Avoid contact between water and live components.
- Before changing the location of the dehumidifier and pump kit, switch it off and then press and hold down the button for manual pump out until there is no more condensate water flowing out of the hose. Then disconnect the mains plug.
- Each time the pump kit is installed or removed, ensure that the safety relay for the dehumidifier is switched off and the mains cable is disconnected.
- Check that the pump kit cables are not damaged.
- Only allow the manufacturer or authorised personnel to carry out work on electric components.
WARNING! Electrocution! Electrocution may occur due to improper or faulty connection to the power supply.
- Check that the connection cable is compatible with the pump kit connection on the dehumidifier.
- Ensure that the connection cable is undamaged.
WARNING! Risk of burn!
- Only allow the manufacturer or authorised personnel to carry out work on internal components.
CAUTION! Risk of injury if pump kit falls out! Pump kit with sliding lock/Secure the lock and check that it fits properly.
Complete emptying before transport and removal The pump must be completely emptied before transporting the dehumidifier and every time the pump kit is dismantled.
WARNING! Electrocution!
- Before dismantling the pump kit and before transporting the dehumidifier, always make sure that the condensate water has been completely pumped out first.
WARNING! Risk of injury and burns during maintenance work!
- Each time the pump kit is installed or removed, ensure that the safety relay for the dehumidifier is switched off and the mains cable is disconnected.
- Only allow the manufacturer or authorised personnel to carry out repairs and maintenance work.
- In the event of malfunctions, switch off the product and secure it so that it cannot be switched back on again.
- Allow any hot components to cool sufficiently before working on them.
ATTENTION! Damage to property!
- Cleaning agents can damage surfaces. Only use mild detergents.
- Only use approved original spare parts.
ATTENTION! Device may be damaged if stored improperly
- Never store pump kit below freezing.
ATTENTION! Risk from materials and substances
- Sort materials according to type and recycle in accordance with local regulations.
- When disposing of auxiliary and operating materials, observe the local regulations and information on the safety data sheets.
Source: manufacturer's operating instructions (Aerial pump kit).
- Depth
- 17 cm
- IP protection class
- IPX4
- Manufacturer
- Aerial
- Voltage
- 230 V
- Width
- 32 cm
- Working range
- 3 to 50°C
- Power
- 85 watts
- Weight
- 4 kg
- Product type
- condensate pump
- Height
- 26 cm
- Shipping Weight
- 4.2 kg