Comedes Demecto 70 – High-Performance Dehumidifier for Large Rooms

The Comedes Demecto 70 is designed to dehumidify larger living areas, basements and storage rooms, as well as spaces with high humidity levels. At 30 °C and 80% relative humidity, its stated dehumidification capacity is 70 litres per 24 hours. Two automatic operating modes, a digital hygrometer, two fan speeds, a timer and a hose connection for condensate drainage allow the appliance to be adapted to different requirements. Actual dehumidification performance depends particularly on ambient temperature and relative humidity.

Key Features at a Glance

  • High dehumidification capacity: 70 L/24 h at 30 °C and 80% RH; maximum 75 L/24 h according to the manufacturer
  • Manufacturer's room-size ratings: up to 120 m² for active dehumidification and up to 240 m² for humidity maintenance, both based on a ceiling height of 2.3 m
  • Continuous drainage option: Hose connection for continuous condensate discharge, provided the drain is correctly installed
  • Automatic functions: Temperature-controlled automatic defrosting, overflow protection and overheating protection

Rated “sehr gut” (“Very Good”) in a 2014 Practical Test

The Comedes Demecto 70 received an overall rating of “sehr gut” (“Very Good”) in a practical test published by Technik zu Hause.de on 10 October 2014. This assessment applies to the appliance tested at that time; the version currently offered may differ in certain technical details. The review highlighted, among other aspects, ease of use, the timer function and low maintenance requirements.

Source and full test report: Technik zu Hause.de, “Praxistest Comedes Demecto 70 Luftentfeuchter”, published on 10 October 2014; test report dated 10 October 2014; award label marked 10/2014. The product category shown on the original label was “Luftentfeuchter bis 500 Euro” (“Dehumidifiers up to €500”). View the original German-language review and assessment.

Designed for High Humidity Levels

The Demecto 70 can help regulate humidity in large basements, storage areas and comparable spaces. When selecting a dehumidifier, the amount of moisture entering the room, the room temperature and the desired relative humidity are just as important as floor area. The ratings of up to 120 m² for active dehumidification and 240 m² for humidity maintenance are manufacturer specifications based on a ceiling height of 2.3 m.

→ Compare All Demecto Models

Dehumidification, Controls and Water Drainage

In standard automatic mode, the desired relative humidity can be set. The Demecto 70 also offers a temperature-dependent comfort mode. An integrated digital hygrometer displays the ambient relative humidity. The two-speed fan and temperature-controlled automatic defrost function support operation within the specified ambient temperature range of 5 to 35 °C. The unit can also assist with dehumidification following moisture incidents; however, it does not replace professional remediation of the underlying cause of dampness or water damage.

Condensate is collected in the 4.8-litre water tank. A float switch automatically stops operation when the tank is full. Alternatively, the hose connection allows continuous condensate drainage if the drain line is installed in accordance with the manufacturer's instructions.

Features and Ease of Use

  • Two automatic modes: adjustable target relative humidity and temperature-dependent comfort mode
  • Digital hygrometer displaying the current relative humidity
  • Timer for delayed start or switch-off, adjustable from 1 to 24 hours
  • Two fan speeds and temperature-controlled automatic defrosting
  • Side carrying handles and castors for moving the unit
  • Washable pre-filter, subject to the manufacturer's cleaning instructions

Use for construction moisture and following water damage: The appliance can assist with drying the room air. It does not replace professional investigation and elimination of the source of dampness, mould remediation or specialist water-damage restoration.

Technical Specifications

FeatureSpecification
Dehumidification capacity70 litres/24 h at 30 °C / 80% RH; maximum 75 litres/24 h
Active dehumidification areaUp to 120 m² at a ceiling height of 2.3 m
Humidity maintenance areaUp to 240 m² at a ceiling height of 2.3 m
Water tank capacity4.8 litres
Drainage optionsInternal water tank or fixed hose connection for condensate drainage
Defrost functionTemperature-controlled automatic defrosting
Safety functionsOverflow protection, overheating protection and automatic stop when the water tank is full
Power consumption800 W
Voltage / frequency220–240 V / 50 Hz
Operating temperature5–35 °C
RefrigerantR290, 153 g
Noise level< 51 dB
Fan speeds2
HumidistatIntegrated
TimerStart / switch-off timer, adjustable from 1 to 24 hours
Dimensions (W × H × D)405 × 632 × 268 mm
Weight19.5 kg

Technical information is based on the manufacturer's product description and user manual for item no. PT94053. Data from the historical 2014 test may differ from the manufacturer's current specifications. The specifications of the actual version offered for sale take precedence.

Frequently Asked Questions About the Demecto 70

Is the Demecto 70 suitable for cooler basements?

According to the manufacturer, the appliance is designed for ambient temperatures of 5–35 °C and features temperature-controlled automatic defrosting. Dehumidification performance can be significantly lower at cooler temperatures. Use on construction sites is also subject to the manufacturer's operating and safety instructions.

How does continuous condensate drainage work?

A suitable drainage hose can be connected to the unit's condensate outlet. This allows the condensate to drain continuously, so the internal 4.8-litre tank does not need to be emptied regularly when the drain line is correctly installed. Follow the manufacturer's instructions when setting up condensate drainage.

What is the difference between active dehumidification and humidity maintenance?

The active dehumidification area of up to 120 m² refers to the area specified by the manufacturer for lowering humidity. The humidity maintenance area of up to 240 m² describes a larger area in which an already regulated humidity level can be maintained. Both figures assume a ceiling height of 2.3 m. Actual capacity requirements depend on factors including room temperature, relative humidity, ceiling height and the amount of moisture entering the room.

Safety instructions for the Comedes Demecto 70

Important: Read the complete manufacturer’s instruction manual before first use. The following information is a summary and does not replace the manual.

  • Flammable R290 refrigerant: The appliance contains flammable R290 refrigerant (propane). Keep away from naked flames and continuously operating ignition sources. Do not pierce or burn the casing or refrigerant circuit.
  • Minimum room size: Install, operate and store the appliance only in rooms with a floor area greater than 12 m². Ensure adequate ventilation.
  • Clearance and positioning: Maintain at least 50 cm clearance from walls and other obstructions. Place on a firm, level and dry surface; keep air inlets and outlets clear. Do not use in wet areas or where exposed to splashing water.
  • Electrical safety: Connect only to a supply of the specified voltage protected by a residual current device (RCD). Do not use with a damaged power cable. Disconnect from the mains before moving or cleaning and when not in use. Never immerse the appliance in water.
  • Before first use: Leave the appliance standing in its final upright position for at least 2 hours before switching it on. Check that the water tank is correctly fitted; empty it before transport and do not tilt the appliance.
  • Children and servicing: Children must not play with the appliance. Children may only carry out cleaning or user maintenance in accordance with the instructions in the manual. Work on the refrigerant circuit and safety-related repairs must be carried out by appropriately qualified professionals.
  • Operation and care: Use only within the specified operating temperature range of 5–35 °C. Do not use methods or agents to accelerate defrosting or for cleaning other than those recommended by the manufacturer.

Full instruction manual and safety information (manufacturer PDF)


Safety instructions

WARNING: Please read the instructions carefully before commissioning. Failure to follow the safety instructions and instructions may result in electric shock, fire and/or serious injury. Keep all safety information and instructions for future reference.

  • Look out! Do not open the unit before the mains plug has been removed from the mains socket. Danger to life through electric shock! Have repairs carried out only by an authorised specialist workshop.
  • Flammable gas Danger This symbol indicates that extremely flammable gas is a danger to health and life.
  • Observe operating instructions This symbol draws your attention to the fact that the operating instructions must be followed before installing and operating the device.
  • Observe operating instructions and operating notes This symbol draws your attention to the fact that the operating instructions and the operating notes contained therein must be considered and observed.
  • Repair instructions, observe technical manual Activities on the refrigeration circuit, such as disposal, repairs and maintenance activities, may only be carried out by persons with a relevant certificate of competence and only in accordance with the manufacturer's specifications. Repair instructions and maintenance and disposal information are available from the manufacturer on request.
  • Danger There is danger to the device or objects in the vicinity of the device.
  • Electrical hazard shock hazard

Safety Instructions

  • Do not use any agents other than those recommended by the manufacturer to speed up the defrosting process or to clean the appliance.
  • The appliance must be stored in a room without continuously operating ignition sources (e.g. naked flames, a gas appliance switched on or an electric heater switched on).
  • Do not puncture or incinerate.
  • Note that the refrigerant is odourless.
  • The device may only be installed, operated and stored in a room with a floor space of more than 12m².
  • Maintenance may only be carried out in accordance with the manufacturer's instructions.
  • The unit must be stored in a well-ventilated area in which the room size corresponds to the room area specified for operation.
  • All work processes that affect safety-relevant aspects (e.g. repairs) may only be carried out by qualified personnel.
  • Store the unit in a safe place to avoid electric shock, flame or injury.
  • Do not immerse this product in water or any other Fluids.
  • If the power cord is damaged, it must be replaced by the manufacturer, its service partner or similarly qualified persons to avoid any danger.
  • Please contact a specialist to have the product repaired. Improper repairs may cause injury to the user.
  • Disconnect the unit from the power supply before moving, cleaning and even when the product is not in use.
  • Please operate the product with the specified electrical voltage.
  • Use this product only as a household appliance and in accordance with its intended use.
  • Do not place any objects on the product.
  • To avoid water leakage, please empty the water tank before moving the product.
  • Do not tilt the appliance, as leaking water may damage the appliance.
  • This appliance may be used by children over 8 years of age and by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge, provided they are supervised or have received instruction in the safe use of the appliance and understand the risks involved. Children must not play with the device.
  • Cleaning and maintenance by the user must not be carried out by children without supervision.
  • Please position the product at a minimum distance of Transport, labelling and storage of the equipment When transporting equipment and parts containing flammable refrigerants, the transport regulations must be observed.
  • 50cm from the wall or other barriers.
  • The operating temperature range for this instrument is 5-35℃.
  • Do not operate your dehumidifier in a wet area.
  • The appliance is not splash-proof.
  • Do not place the appliance on a soft, unstable, uneven or wet surface to avoid increased noise, vibration, water leakage or electric shock during operation.
  • Never insert objects (such as a thin rod) into the unit.
  • This can cause damage to the unit.
  • Please disconnect the device when you switch it off or do not intend to use it for a longer period of time.
  • The disposal of units with flammable refrigerants must be carried out in accordance with national regulations.
  • The maximum number of units that can be stored together is determined by local regulations.
  • The device must be stored in such a way that no mechanical damage can occur.
  • The working area of the device must be at least 12m². It must be ensured that there are no flammable materials in the working area of the device.
  • Use the on/off switch to switch the unit on and off.
  • Never use the plug to turn the unit on and off.
  • Do not clean the dehumidifier with water.
  • Never spray the appliance with water.
  • Do not spray the unit with flammable liquids or cleaning agents.
  • Do not touch the ventilation slots.
  • Do not cover the air inlet or outlet.
  • Do not use the device if the power cord is damaged.
  • Do not use the device in hermetically sealed rooms.
  • Always operate the appliance for at least 35 minutes (risk of compressor damage). The automatic switching of the unit in automatic mode is no problem.Keep the water tank free of foreign objects.
  • Install the unit away from heaters or heat generating devices.
  • The device must not be used in environments with high dust or chlorine content.
  • Only use the unit if your power outlet is equipped with an RCD (FI) protection switch.
  • Never switch the device on or off with wet hands.
  • Do not attempt to make repairs or other adjustments, both electrical and mechanical, to the unit yourself.
  • Do not let children play with the packaging, such as plastic sheeting.
  • Keep a sufficient distance from the air outlet of the unit.
  • Do not operate the device near explosive, flammable or corrosive materials.
  • Insert the mains plug firmly and securely into the socket.
  • Do not operate the dehumidifier via a multiple socket or extension cord.
  • Appropriate use The dehumidifier is only intended for dehumidifying privately used rooms (e.g. living rooms, bedrooms, storage rooms or cellars). The user must comply with the operating parameters specified in this manual.
  • The machine may only be used for its intended purpose. Any other use beyond this is not in accordance with its intended purpose. The user/operator and not the manufacturer is liable for any damage or injury of any kind caused by this.

Operating instructions

  • The device is designed for a temperature range between 5 and 35°C. Below 5°C the humidity tends to be very low, so you do not need to use a dehumidifier. Above 35°C, the overheating protection may automatically switch off the unit. The unit is not approved for operation outside the temperature range.
  • The dehumidifier warms the air so that it can dehumidify optimally. Therefore the room temperature can rise by 1-2 degrees. This is quite normal and increases the efficiency of the unit.
  • In order to work in an energy-efficient manner, the unit switches off automatically when the set humidity is reached. If the humidity rises again, the unit switches on again automatically.
  • Always take the device from the front if you want to carry it.
  • When the water tank is full, the appliance switches off automatically.

Source: manufacturer's operating instructions (Comedes Demecto 70).

Max. Dehumidification capacity
75 liters/day
Display
LED
Refrigerant
R 290
Operating time counter
yes
Power
800 watts
Air outlet
At the top
Fan
axial
Sound pressure
51 dB(A)
WiFi
no
Depth
26,8 cm
Weight
19 kg
Hygrostat
Built-in, electronically
Casing
Plastic
IP protection class
no
Water tank
4,8 liters
Height
63,2 cm
Air inlet
At the back
Color
White
Width
40,5 cm
Voltage
230 V
Manufacturer
Comedes
Functionality
Condensation dryer
Product type
dehumidifier
Working range
5 to 35°C
Control
Digital control
Condensate pump
no
Room volume
ca. 46 m³ bei 2,3 m Höhe
Shipping Weight
20.1 kg
This item has already been rated. A written review has not yet been submitted.

 
43,99 €

incl. 19 % VAT, excl. Shipping costs

 
266,31 €

incl. 19 % VAT, excl. Shipping costs

 
399,99 €

incl. 19 % VAT, excl. Shipping costs

 
619,99 €

incl. 19 % VAT, excl. Shipping costs

 
169,90 €

incl. 19 % VAT, excl. Shipping costs