Dehumidifier AD 110 by Aerial

The Aerial AD 110 dehumidifier is a versatile wall-mounted device, from living room to waterworks.

It has a robust stainless steel housing, which means that the dehumidifier is also suitable for commercial use. Thanks to the simple housing made of brushed stainless steel, it adapts inconspicuously to any room. It also has a space-saving wall mount. The dehumidifier is suitable for heated rooms up to 140 m³ and unheated rooms up to 70 m³.

Due to the demand-controlled hot gas defrosting, the AD 110 air dehumidifier can be used at very different room temperatures, including sauna areas, storage rooms, cellars, archives, waterworks, etc.

The integrated condensate pump makes the air dehumidifier work completely autonomous. It has an energy-efficient axial fan and a maintenance-friendly cooling circuit with a service connection. In addition, the aerial dehumidifier has a failure protection, which means that it restarts automatically after a power failure.

Product information
Device name Aerial AD 110 dehumidifier
Manufacturer Aerial
Country of manufacture Germany
Mode of operation Condensation dryer with energy recovery
Room size Heated rooms up to 140 m³
Unheated rooms up to 70 m³
Use area Waterworks, storage rooms, cellars, garages, archives, fitness and sauna areas, changing rooms, etc.
Material Stainless steel
Color bare, brushed
Fan axial
Air inlet left
Air outlet front
Air filter washable
Compressor Rotary compressor
Condenser Copper tube with aluminum fins
Evaporator Copper tube with aluminum fins
Defrosting automatic, thermostat controlled (hot gas defrost)
Condensate tray Stainless steel
Condensate drainage integrated condensate pump
Hygrostat mechanisch, built-in
Control Fully automatic hygrostat control, operation and control panel, hour meter, electricity meter (MID), 2-stage fan control
Installation Wall mounting, included wall rail
Connection type 3 m power cord with warm device coupling and Schuko plug
Specialities Configuration memory: automatic restart in the event of a power failure with the last set settings

Technical details
Dehumidification capacity at + 30 °C / 80 % rH: 15 liters/day
at + 20 °C / 60 % rH: 8,5 liters/day
at + 15 °C / 70 % rH: 8 liters/day
Condensate tank size 14 liters
Drain hose Internal diameter 12 mm, external diameter 15 mm (optionally available as accessories), 3 m length
Delivery head 3 m
Working range from + 3 °C to + 30 °C / from 35 % rH to 95 % rH
Weight 18.5 kg
Refrigerant R 1234 YF
Quantity of refrigerant 0.14 kg
CO² equivalent 0.56 kg
CFC Notice The device does not contain any fluorinated greenhouse gases
Air volume 225 m³/hour
Sound pressure level at 2 m distance: fan stage 1: 46 dB(A)
Supply voltage 230 volts / 50Hz / 16 amps
maximum power consumption 350 watts
Power consumption at + 30 °C / 80 % rH: 330 watts
at + 20 °C / 60 % rH: 236 watts
at + 15 °C / 70 % rH: 215 watts
maximum current consumption 1.43 amps
Protection type IP 54
Dimensions Width: 330 mm
Height: 490 mm
Depth: 280 mm

Safety instructions

WARNING! Risk of explosion, burns and poisoning from refrigerants! The appliance contains an odourless, flammable refrigerant which, if handled incorrectly, could result in explosions and fire as well as injuries and burns. The refrigerant circuit is pressurised.

  • Do not use any objects to accelerate the thawing process.
  • Do not store the dehumidifier in rooms with permanent sources of ignition, such as open flames, operational gas appliances or electric heaters.
  • Do not drill open or ignite dehumidifiers.
  • Only operate the appliance in an adequately ventilated room larger than 4 m².
  • Any work to the refrigerant circuit must be performed by the manufacturer or the manufacturer’s authorised technical personnel. Before working on the refrigerant circuit, it must be depressurised using the designated mechanisms.
  • Observe the national regulations for gas installations.
  • Do not dump refrigerants or dispose of them as household waste.
  • Avoid coming into contact with the refrigerant.

Intended use and conditions of use

The dehumidifier is used to remove humidity from the air where there is atmospheric pressure in closed indoor rooms, such as basements, garages or warehouses, and is designed to be wall mounted.

The dehumidifier must only be mounted, used and stored in rooms larger than 4 m².

The dehumidifier must only be used in compliance with the Technical Data (see last page).

Persons with physical, sensory or mental restrictions and children are not permitted to use the dehumidifier.

Every user must have read and understood the operating instructions.

Foreseeable misuse

The dehumidifier must not be used:

  • In rooms with potentially explosive atmospheres.
  • In rooms with an aggressive atmosphere (e.g. caused by chemicals).
  • In rooms with water with a pH value below 7.0 or above 7.4.
  • In rooms with salt or liquids with a salt content > 1 %, e.g. brine baths.
  • In rooms with ozone-treated air, high solvent concentrations or high dust pollution.

WARNING! Electrocution! Working on live components or water on live components can cause life-threatening electrocution.

  • Avoid contact between water and live components.
  • Always switch off and unplug the dehumidifier before moving it to another location.
  • Only allow the manufacturer or authorised personnel to carry out work on electric components.

WARNING! Risk of dehumidifier falling as a result of incorrect assembly!

  • Only use the wall mount provided and universal installation kit.
  • The dehumidifier must be installed by two people.
  • Make sure that the wall is sound and capable of bearing the load.

WARNING! Crushing as a result of instability!

  • Transport the dehumidifier in an upright position and secure it so that it cannot tip over or slip.
  • Position the dehumidifier on a stable, even surface.

WARNING! Risk of cuts and crushing from incorrect handling during transport

  • Do not reach into openings such as air filters.
  • The dehumidifier must be transported by two people using appropriate lifting and transport equipment.

ATTENTION! Inadequate appliance output!

  • Do not bend the discharge hose.
  • Do not place any objects on the hose.

Requirements

The air must circulate freely. Do not cover the air openings. There must be a clearance of at least 100 cm in front of the air outlet and the air filter.

There must be at least 10 cm between the top of the wall mount and the nearest object to allow the device to be mounted.

There must be at least 60 cm between the bottom of the wall mount and the nearest object.

Electrical connection

  • Make sure that the supply voltage is the same as the connection voltage in the technical data.
  • Provide an adequate fuse for the socket and the power supply.
  • Install an earth leakage circuit breaker in damp rooms and building sites.
  • Make sure that the mains plug is suitable for the socket of the building.
  • Make sure that the socket used is earthed.

NOTE: Allow the dehumidifier to rest in its final position for approx. 15 minutes before starting up, after transport and after prolonged storage.

WARNING! Damage to health from dust!

  • Only clean the dehumidifier with compressed air in open spaces.
  • Wear a protective mask and goggles.

WARNING! Risk of injury from rotating fan. Before opening the bezel:

  • Disconnect the mains plug and wait at least 15 s.
  • Make sure that the fan has stopped.

CAUTION! Risk of burning from hot cables! Some cables inside the housing can get hot and cause slight burns.

  • Allow the cables to cool down sufficiently.

WARNING! Risk of electrocution from leaking condensate water! After cleaning the drip tray, make sure that the drain hose (Pos. 2) is inserted in the pump opening.

ATTENTION! Damage to property!

  • Cleaning agents can damage surfaces. Only use mild detergents.
  • Only use approved original spare parts.

WARNING! Poisoning from refrigerant, burns, crushing or electrocution during maintenance work!

  • Only allow the manufacturer or authorised personnel to carry out repairs and maintenance work.
  • In the event of malfunctions, switch off the dehumidifier and secure it so that it cannot be switched back on again.
  • Allow any hot components to cool sufficiently before working on them.

ATTENTION! Risk from materials and substances

  • Sort materials according to type and recycle in accordance with local regulations.
  • When disposing of auxiliary and operating materials, observe the local regulations and information on the safety data sheets.

CAUTION! Injury!

  • Do not stack more than two dehumidifiers on top of each other.
  • Secure the dehumidifiers so that they do not fall over.

Source: manufacturer's operating instructions (Aerial AD 110, V1.0_06-2020).

Refrigerant
R 1234 YF
Power
350 watts
Air inlet
On the left
Depth
28 cm
Product type
dehumidifier
Casing
Stainless steel
WiFi
no
Water tank
14 liters
Max. Dehumidification capacity
15 liters/day
Operating time counter
yes
IP protection class
IP54
Room volume
0140 m³
Manufacturer
Aerial
Sound pressure
46 dB(A)
Voltage
230 V
Height
49 cm
Display
LED
Working range
3 to 30°C
Air outlet
At the front
Color
Blank
Functionality
Condensation dryer
Weight
19 kg
Width
33 cm
Hygrostat
Built-in, mechanically
Control
Variable hygrostat rotary control
Air output
225 m³/h
Fan
axial
Condensate pump
no
Shipping Weight
30 kg
This item has already been rated. A written review has not yet been submitted.

 