Window Fans
Vortice Vario at a glance
All models have a housing made of UV-resistant ABS plastic in white, an electric internal shutter, thermal overload protection, protection type IPX4 and protection class II. The AR-Q version has a motor with self-lubricating plain bearings, the AR-S version a ball-bearing motor with higher performance.
| Model | Nominal width | Air flow max. | Power max. | Sound pressure (3 m) |
| Vortice Vario 150/6 AR-Q | 150 mm | 235 m³/h | 25 W | 37.5 dB(A) |
| Vortice Vario 150/6 AR-S | 150 mm | 380 m³/h | 35 W | 49.6 dB(A) |
| Vortice Vario 230/9 AR-Q | 230 mm | 480 m³/h | 26 W | 35.6 dB(A) |
| Vortice Vario 230/9 AR-S | 230 mm | 700 m³/h | 35 W | 43.6 dB(A) |
| Vortice Vario 300/12 AR-Q | 300 mm | 1,050 m³/h | 45 W | 40.2 dB(A) |
| Vortice Vario 300/12 AR-S | 300 mm | 1,650 m³/h | 75 W | 53.6 dB(A) |
Data according to the manufacturer's data sheet at 50 Hz. Actual performance depends on the installation situation.
Installation accessories for window, wall and roof
For installation in separately opening double windows the manufacturer offers the kits DG1 (distance 230–300 mm) and DG2 (30–43 mm). Further accessories are the threaded bolt set Kit MU for wall installation, roof and storm hoods (DH), the darkroom light-trap attachment DKV 230 and connection flanges (TC) for duct connection. You will find all parts under Wall-mounted fan accessories. Which parts fit which model is shown on each product page.
Window fan, wall-mounted fan or window trickle vent?
The Vario fans can be installed in a window or a wall and belong to the axial fans. For pure wall installation without a window you will find further devices under wall-mounted fans. A window trickle vent, on the other hand, is a different product: a passive ventilation element in the window frame without a motor.
Areas of application
- Kitchens and bathrooms with a window
- Offices, workshops and small commercial rooms
- Rooms where window or wall installation is desired
The actual effect depends on room size, construction and installation situation. A specific effect is not guaranteed. According to the manufacturer's instructions, the devices may only be installed by qualified personnel.
[FAQ]