Lubra dehumidifier DHP 18
A compact and robust, but still quiet professional dehumidifier for the permanent elimination of excessively high humidity. For living, office and basement rooms up to 250 m³.
Due to the integration of a hygrostat and an overflow-proof container, the device is particularly suitable for unsupervised operation. If necessary, a hose can also be connected for continuous condensate disposal.
The dehumidifier Lubra DHP 18 with its built-in hygrostat, can switch on automatically when the desired humidity is exceeded. If the value falls below this, it switches itself off again. This process is repeated continuously so that you only have to set the desired humidity value once and the dehumidifier works by itself. This dehumidifier is maintenance-free, so there are no follow-up costs for maintenance and consumables.
| Devie-Name | Lubra dehumidifier DHP 18 |
| Manufacturer | Lubra |
| Country of Manufacture | Portugal |
| Room size up to | 250m³ |
| Operation method | Condensation dryer with energy recovery |
| Weight | 25 kg |
| Material | Sheet steel (coated) |
| Color | White |
| Ventilator | axial |
| Air inlet | back |
| Air outlet | front |
| Air filter | Fabric filter, washable |
| Compressor | Reciprocating compressor |
| Capacitor | Copper pipe with aluminum fins |
| Evaporator | Copper pipe with aluminum fins |
| Defrost | automatic thermostat control (compressor off) |
| Condensate pan | plastic |
| Condensate drainage | Integrated collecting container (overflow-protection with control lamp) or direct drain |
| Hygrostat | eelectronic, built-in |
| Control panel | Membrane keypad |
| Controls | Hygrostat control range 40 to 60% RH in 10% steps, continuous operation, 5 levels |
| Installation | rollable with recessed grips on the side, mobile or on the wall |
| Connection type | 2,2 m with EU plug |
| More product details | Configuration memory, the last saved settings are restored in the event of a power failure |
| Dehumidification performance | at + 30 °C / 80 % RH: 18,0 Liters/Day at + 20 °C / 80 % RH: 10,6 Liters/Day at + 20 °C / 60 % RH: 6,2 Liters/Day at + 10 °C / 60 % RH: 2,0 Liters/Day |
| Condensate tank size | 5 Liters |
| Drain hose | Inner diameter 14 mm, outer diameter 18 mm (optionally available as an accessory) |
| Workspace | from + 5 °C to + 32 °C / from 35 % RH to 100 % RH |
| Refrigerant | R 290 |
| Refrigerant amount | 0,15 kg |
| CFC notice | The device does not contain any fluorinated greenhouse gases |
| Air volume | 250 m³/Hour |
| Sound pressure level | at 3 m distance: Fan level 1: 45 dB(A) |
| Supply voltage | 230 Volt / 50 Hz / 16 Ampere |
| Maximum power consumption | 460 Watt |
| Power consumption | at + 20 °C / 60 % RH: 341 Watt |
| Maximum power consumption | 2 Ampere |
| Dimensions | Width: 330 mm Hight: 560 mm Depth: 360 mm |
1. General safety instructions
The operator must make the operating instructions available to the user and make sure that the user understands the contents.
- The appliance contains flammable refrigerant
- Read the supplied instructions / warnings
- Read the maintenance instructions
ATTENTION Fire hazard/flammable materials
- Read the operating instructions
- Do not use any means other than those recommended by the manufacturer to accelerate the defrosting process or to clean the appliance.
- The appliance may only be stored in a room without continuously operating ignition sources (e.g. open fire, operating gas or electric heaters).
- Do not pierce or burn.
- Please note that refrigerants may not have an odour.
- The appliance should be installed, operated and stored in a room with a floor area of more than 4m².
ATTENTION The appliance may be used by children aged 8 and over and by persons with reduced physical, sensory or mental abilities or lack of experience and / or knowledge if they are supervised or have been instructed in the safe use of the appliance and have understood the resulting hazards. Children must not play with the appliance. Cleaning and user maintenance must not be carried out by children without supervision.
- Compliance with national gas regulations must be observed.
- R290 has a low global warming potential (GWP) of 3 and an ozone depletion potential (ODP) of 0.
- The maximum amount of refrigerant is 0.150kg.
- Keep the ventilation openings free from obstructions.
- The appliance must be stored so that no mechanical damage occurs.
- The appliance must be stored in a well-ventilated area with a room size appropriate for operation.
2. Safety instructions
ATTENTION This dehumidifier must not be used in rooms under the following conditions:
- potentially explosive atmosphere
- extremely polluted atmosphere
- high concentration of solvents
- extremely high dust levels
Always connect the appliance earthed: Only operate the appliance with a earthing-contact plug and an earthed socket. The earthing-contact plug is an essential safety feature that helps prevent a risk of fire or electric shock.
Protect the power cable from damage: Never operate an appliance with a damaged power cable, as this can lead to fire or electric shock. If the power cable is damaged, it must be replaced with a cable of the same type and the same amperage.
Extension cables: Extension cables must be earthed and be able to supply the appropriate voltage to the appliance.
Handle the appliance with care: Do not drop the dehumidifier, do not throw it and do not open it by force. Rough handling can damage the components or the cables and cause hazards.
Operate the appliance on a stable surface: Only operate the appliance on a stable, level surface, for example on the floor or a sturdy table, so that the dehumidifier cannot fall and cause injury.
Keep the appliance away from water: Never operate the appliance in running or standing water - risk of injury from electric shock! Do not store or operate the appliance outdoors. If electrical cables or components become wet, dry them thoroughly before using the appliance. If in doubt, please do not switch on the dehumidifier. Please contact an authorised dealer or a recognised workshop.
Keep air inlets clear: Do not place the dehumidifier too close to curtains, walls or other places that could obstruct the air inlet. This can lead to overheating of the appliance and a risk of fire or electric shock.
Keep the filter clean: Always use a clean air filter. Prevent any material from clogging the filter. This can lead to overheating of the dehumidifier. Never use the appliance without a filter. Check and clean the filter if necessary, always before you switch on the dehumidifier. Prevent oil, grease or other contaminants from entering the appliance.
Keep electrical components dry: Never let water get into the electrical components of the dehumidifier. If electrical cables or components become wet for any reason, dry them thoroughly before using the appliance. If in doubt, please do not switch on the dehumidifier. Please contact an authorised dealer or a recognised workshop.
5. Assembly and transport Please observe the following instructions for assembly and transport:
- The air inlets and outlets must not be covered while the appliance is in operation.
- The dehumidifier must be switched off before any transport. Unplug the mains plug from the socket and empty the water container.
- During transport, the appliance must be secured on a firm surface so that it does not roll away.
- Always transport the dehumidifier upright.
- This dehumidifier is only suitable for drying air.
- If the appliance is stored or transported in a horizontal position for several minutes, it must then be set up upright for at least 30 minutes before it is switched on. This allows the oil to return to the compressor.
6. Operating instructions ATTENTION
- Only operate the dehumidifier in an upright position.
- Connect the appliance to a standard socket with appropriate voltage and current.
- If the appliance switches off for any reason, wait five minutes before switching it on again. This avoids damage to the compressor.
- Check daily that the dehumidifier is working properly.
- Protect floor surfaces from water.
This dehumidifier has been designed for an electrical installation of 230 V~50Hz. Make sure that the sockets are earthed and all safety precautions have been taken.
Source: manufacturer's operating instructions (Lübra DHP 12/18/25/30).
- Color
- White
- WiFi
- no
- Power
- 460 watts
- Height
- 56 cm
- Water tank
- 5 liters
- Air output
- 250 m³/h
- Refrigerant
- R 290
- Product type
- dehumidifier
- Room volume
- 0250 m³
- Air inlet
- At the back
- Sound pressure
- 45 dB(A)
- Display
- LED
- Hygrostat
- Built-in, electronically
- Functionality
- Condensation dryer
- IP protection class
- no
- Manufacturer
- Lübra
- Weight
- 25 kg
- Voltage
- 230 V
- Depth
- 36 cm
- Fan
- axial
- Air outlet
- At the front
- Casing
- Sheet steel
- Working range
- 5 to 32°C
- Width
- 33 cm
- Max. Dehumidification capacity
- 18 liters/day
- Control
- Membrane keypad
- Condensate pump
- no
- Shipping Weight
- 25 kg