Vortice Lineo Quiet In-Line Mixed Flow Fan LINEO QUIET 125 – Sound-Insulated Mixed Flow Fan for Extremely Quiet Operation
The Vortice Lineo Quiet in-line fan LINEO QUIET 125 combines the high pressure and airflow performance of the proven Lineo series with an integrated, highly effective sound insulation system. Designed for settings where powerful supply and extract ventilation is required with minimal noise levels, this sound-proofed in-line fan is perfectly suited for installation in ventilation ducts (nominal size 125 mm ).
Thanks to its sound-absorbing internal lining and flow-optimised housing geometry, the Lineo Quiet reduces both breakout and duct noise to a minimum. The proven mounting bracket also allows for easy unclipping of the motor unit for quick cleaning and maintenance – without dismantling the ductwork system.
Key Product Benefits at a Glance
- ✔ Extremely Quiet Operation: Integrated acoustic insulation effectively dampens airflow and motor noise.
- ✔ High Pressure Performance: Mixed-flow impeller provides strong air delivery even against higher system resistance.
- ✔ Durable & Maintenance-Free: Ball-bearing motor designed for at least 30,000 hours of continuous operation with thermal overload protection.
- ✔ User-Friendly Clip-Out System: The motor unit can be removed from the mounting brackets in just a few steps.
- ✔ Robust Plastic Housing: High-quality, self-extinguishing polypropylene (V0) for maximum safety.
Whisper-Quiet Ventilation for Demanding Spaces
The Vortice Lineo Quiet is the ideal solution for living spaces, offices, meeting rooms, libraries, hotels, medical practices, or sanitary areas – wherever disruptive ventilation noise must be avoided. With its compact dimensions, it can easily be installed even in confined spaces such as suspended ceilings or ventilation shafts.
| Feature | Value / Specification |
|---|---|
| Model | LINEO QUIET 125 |
| Maximum Airflow | 220 m³/h |
| Maximum Pressure | 137.3 Pa |
| Voltage | 230 V / 50 Hz |
| IP Rating / Protection Class | IP45 |
| Appliance Class | II |
| Sound Pressure Lp-2m | 26.9 dB(A) |
| Current Consumption | 0.13 A |
| Maximum Air Temperature | 45 °C |
| Colour | Light grey / White |
| Housing Material | Self-extinguishing plastic with integrated sound insulation (V0) |
| Maximum Speed | 1,880 RPM |
| Nominal Diameter / Duct Connection | 125 mm |
| Fan Features | Sound-insulated housing, in-line duct installation, removable motor unit, thermal overload protection |
| Motor Type | Ball-bearing mounted, multi-stage controllable |
| Fan Type | Mixed-flow in-line fan / Sound-proofed duct fan |
Notes on Model Variants in the Lineo Quiet Series:
Different versions are available within the Lineo Quiet Series:
• Standard "Quiet": Multi-stage operation, controllable via external switches or control units.
• "Quiet T" (Timer): Equipped with an integrated, adjustable run-on timer (2 to 25 minutes).
Package Contents
|
Compliance
- These appliances are designed for use in residential and commercial properties.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- The appliance must be installed by a professionally qualified electrician.
- The electrical system to which the product is connected must be in compliance with applicable regulations.
- An omnipolar switch with a contact opening distance of 3 mm or higher should be provided for installation, enabling complete disconnection under overvoltage category III conditions.
- Products equipped with single-phase wiring (M) engines ALWAYS require connection to 220-240V (or only 230V where required) single-phase lines. Any kind of modification shall be considered as product tampering and shall nullify the relative warranty.
- The control accessories must be installed in premises with a room temperature that does not exceed 25°C.
- The devices whose technical specifications indicate both the frequency of 50Hz and 60Hz, can operate at both frequencies without requests from the user.
Duct and window - wall fan units
Precautions must be taken to prevent gas coming from the gas flue pipe or from other fuel combustion units from entering into the room.
Warning: this symbol indicates precautions that must be taken to avoid injury
- Do not use this appliance for functions other than those described in this instruction booklet.
- After removing the appliance from its packaging, ensure that it is complete and undamaged. If in doubt contact a professionally qualified electrician or VORTICE*. Do not leave packaging within the reach of children or infirm persons.
- Certain fundamental rules must be observed when using any electrical appliance, including: a) do not touch it with wet or damp hands; b) do not touch it while barefoot.
- If you decide to stop using the appliance, switch it off and disconnect it from the power supply, storing it out of reach of children and infirm persons.
- Do not operate the appliance in the presence of inflammable vapours (alcohol, insecticides, petrol, etc.)
- Do not sit or place objects on or in the appliance.
Caution: this symbol indicates precautions that must be taken to avoid damaging the appliance
- Do not make modifications of any kind to this appliance.
- Do not expose this appliance to the weather (rain, sun, etc.)
- The inside of the appliance should be cleaned only by qualified personnel (fig. 27).
- Do not immerse the appliance or any parts of it in water or other liquids. Refer to the relevant instructions to clean the appliance (fig. 26-28).
- Regularly inspect the appliance for visible defects. If any are found, do not operate the appliance and contact VORTICE* immediately.
- If the appliance does not function correctly or develops a fault, contact VORTICE* immediately and ensure that only original VORTICE spares are used for any repairs.
- Should the appliance be dropped or suffer a heavy blow, have it checked immediately by VORTICE*.
- The appliance is double insulated and therefore does not need to be earthed.
- The electrical power supply / socket to which the appliance is to be connected must be able to provide the maximum electrical power required by the appliance. If it cannot do this, contact an electrician to make the necessary modifications.
- Switch off the appliance at the installation's main switch: a) if the appliance does not function correctly; b) before cleaning the outside of the appliance; c) if the appliance is not going to be used for any length of time.
- The appliance cannot be used to control activation of water heaters, room heaters, etc. and it must not exhaust into the hot air flues of such appliances.
- The room must have an adequate source of replacement air for this appliance to function effectively. Moreover, if there is any non-sealed combustion based appliance such as a water heater, gas stove, etc. in the same room, air replacement must be sufficient for all appliances to work effectively together.
- The appliance must discharge into a single duct (dedicated to this product).
- Keep the appliance’s inlet and outlet grilles free to ensure an optimum flow of air.
- The appliance’s outlet and inlet ports must always be connected to a suitable duct (fig. 2).
- Specifications for the power supply must correspond to the electrical data on data plate A. (Fig.3)
- This symbol means that the operation must be performed by professionally qualified personnel.
*(or an authorized VORTICE dealer if you are outside the UK-Ireland territory)
N.B.
- All versions of 100-125-150-160-200 appliances are fitted with a safety overtemperature device.
- (Fig. 12.1) LINEO 100 QUIET and LINEO 150 QUIET are provided with two fittings that allow to reduce the product diameter (inlet and outlet side) respectively from 125 to 100 mm and from 160 to 150 mm.
*(or an authorized VORTICE dealer if you are outside the UK-Ireland territory)
Source: manufacturer's operating instructions (Vortice Lineo Quiet, pages 12–13).
- Air output
- 220 m³/h
- Sound pressure
- 26.9 dB(A)
- Voltage
- 230 V / 50 Hz
- Air pressure max in Pa
- 137.3 Pa
- Model
- LINEO QUIET 125
- Power
- 27 watts
- Amperage
- 0.13 A
- Temperature max.
- 45 °C
- Dimensions
- 125 mm
- Revolutions
- 1,880 RPM
- Product type
- duct fan
- IP protection class
- IP45
- Shipping Weight
- 4 kg